How a dental lab starts with clear aligners
To start producing clear aligners, a dental lab needs a resin 3D printer for the models with washing and curing equipment, a thermoforming machine, aligner sheet material, a way to trim and finish the aligners, and a source of treatment plans, either a trained planner with software or an outside planning service. Many labs that already print models need only the thermoformer, the material and the plans.
The workflow in one paragraph
The dentist scans the patient and sends the scan and instructions. A treatment plan is made and approved by the dentist. The lab receives one model per stage, prints the models, washes and cures them, thermoforms a sheet of plastic over each model, cuts the aligner along the trim line, finishes the edges, cleans, labels and packs the aligners in order. Each step needs equipment and a short written procedure.
Equipment and materials
| Item | What it does | What to check before buying |
|---|---|---|
| Resin 3D printer | prints one model per stage | accuracy, build plate size, how many models per print, resin cost |
| Model resin | material of the printed models | made for dental models, stable under thermoforming heat |
| Wash and cure units | clean uncured resin and finish curing | sized for your build plate, follows the resin maker's instructions |
| Thermoforming machine | forms the plastic sheet over the model | pressure or vacuum, sheet sizes, heating control |
| Aligner sheets | material of the aligner | thickness, material type, documentation for medical use |
| Trimming tools | cut the aligner along the trim line | hand tools, a trimming machine or a laser, depending on volume |
| Finishing tools | smooth and polish the edges | burs and polishers for thermoplastics |
| Labelling and packaging | keeps stages in order | stage number on each aligner bag, patient code not name |
Printing the models
Aligners copy the model, so any error in the model becomes an error in the aligner. Models should be printed with the resin and settings the printer maker recommends for dental models, washed and cured fully, and checked for warping. Many labs print hollow models to save resin, with drainage holes so that uncured resin does not stay inside. The stage number can be embossed on the base of each model so that it cannot be mixed up.
Thermoforming and the choice of material
Thermoforming heats the sheet until it softens and presses it over the model with air pressure or vacuum. The forming changes the material. Ryu and colleagues measured several aligner materials before and after thermoforming and found changes in thickness and mechanical properties, so the thickness of the finished aligner is less than the thickness of the sheet, and not equal everywhere. Labs should follow the material maker's heating time and temperature exactly and keep a record of the settings used.
Sheet materials for aligners include PET-G and various polyurethane and multilayer materials, in thicknesses that commonly range from about 0.5 to 1 mm. The choice depends on the stage of treatment, the movements planned and the dentist's preference. Retainers often use different materials than active aligners. Ask every supplier for the documentation that the material is intended for intraoral use.
Trimming and finishing
The trim line determines how the aligner holds and how comfortable it is. Cowley and colleagues showed that the height and shape of the edge change the retention of thermoformed aligners. At low volume, trimming by hand along a line marked on the model is enough. At higher volume, labs often move to a trimming machine that follows the digital trim line exported with the plan. After cutting, the edges are smoothed and polished, and each aligner is checked on its model.
The source of treatment plans
Planning is the step that most labs find hardest to start. A planner needs software, training in tooth movement and someone with orthodontic knowledge to review the plans. The alternative is an outside planning service that returns the models for each stage and the trim line, ready to print. A lab can also start with outsourced plans and move simple cases in-house later, when volume is steady.
Regulation
Aligners made by a lab on a dentist's written prescription for one specific patient are custom-made medical devices in the European Union. The Medical Device Regulation sets the rules for them in Article 52(8) and Annex XIII, including a statement for each device and documentation of how it was made. Serbia has its own medical device law, and other countries have their own regulators. Check the rules that apply in your country before you deliver the first aligners.
A start in eight steps
- Talk to the dentists you already work with and agree on how cases will be sent and approved.
- Decide where plans will come from, in-house or outsourced.
- Buy or check the printer, resin and post processing equipment.
- Choose a thermoformer and one or two sheet materials to start with.
- Write a short procedure for printing, forming, trimming, cleaning and packing.
- Make a few test series on models and check fit and edges.
- Prepare the regulatory documentation for custom-made devices.
- Start with simple cases and collect feedback from the dentist after every case.
Quality checks for every series
- The number of aligners matches the number of stages in the plan, for both arches.
- Each aligner sits fully on its own model, without rocking or gaps at the edges.
- Edges are smooth, and no attachment dimple has been cut through.
- Aligners are clean, dry and packed in the order of wear, with the stage number visible.
- The batch record notes the material, the sheet thickness and the thermoforming settings.
The first series show where the procedure needs work. Fit on the model, smooth edges and correct order of stages matter more at the start than speed.
Sources
- Ryu JH, Kwon JS, Jiang HB, Cha JY, Kim KM. Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic aligners. Korean J Orthod. 2018;48(5):316-325. https://doi.org/10.4041/kjod.2018.48.5.316
- Cowley DP, Mah J, O'Toole B. The effect of gingival-margin design on the retention of thermoformed aligners. J Clin Orthod. 2012;46(11):697-702.
- Regulation (EU) 2017/745 of the European Parliament and of the Council on medical devices, Article 52(8) and Annex XIII (custom-made devices). https://eur-lex.europa.eu/eli/reg/2017/745/oj
This article is general professional information for dental labs and dentists. It is not a diagnosis or a treatment plan for any patient. The treating dentist decides on every treatment.