Coming soon: early access is open for dental labs and clinics.
okluzo

How a dental lab starts with clear aligners

To start producing clear aligners, a dental lab needs a resin 3D printer for the models with washing and curing equipment, a thermoforming machine, aligner sheet material, a way to trim and finish the aligners, and a source of treatment plans, either a trained planner with software or an outside planning service. Many labs that already print models need only the thermoformer, the material and the plans.

The workflow in one paragraph

The dentist scans the patient and sends the scan and instructions. A treatment plan is made and approved by the dentist. The lab receives one model per stage, prints the models, washes and cures them, thermoforms a sheet of plastic over each model, cuts the aligner along the trim line, finishes the edges, cleans, labels and packs the aligners in order. Each step needs equipment and a short written procedure.

Equipment and materials

ItemWhat it doesWhat to check before buying
Resin 3D printerprints one model per stageaccuracy, build plate size, how many models per print, resin cost
Model resinmaterial of the printed modelsmade for dental models, stable under thermoforming heat
Wash and cure unitsclean uncured resin and finish curingsized for your build plate, follows the resin maker's instructions
Thermoforming machineforms the plastic sheet over the modelpressure or vacuum, sheet sizes, heating control
Aligner sheetsmaterial of the alignerthickness, material type, documentation for medical use
Trimming toolscut the aligner along the trim linehand tools, a trimming machine or a laser, depending on volume
Finishing toolssmooth and polish the edgesburs and polishers for thermoplastics
Labelling and packagingkeeps stages in orderstage number on each aligner bag, patient code not name

Printing the models

Aligners copy the model, so any error in the model becomes an error in the aligner. Models should be printed with the resin and settings the printer maker recommends for dental models, washed and cured fully, and checked for warping. Many labs print hollow models to save resin, with drainage holes so that uncured resin does not stay inside. The stage number can be embossed on the base of each model so that it cannot be mixed up.

Thermoforming and the choice of material

Thermoforming heats the sheet until it softens and presses it over the model with air pressure or vacuum. The forming changes the material. Ryu and colleagues measured several aligner materials before and after thermoforming and found changes in thickness and mechanical properties, so the thickness of the finished aligner is less than the thickness of the sheet, and not equal everywhere. Labs should follow the material maker's heating time and temperature exactly and keep a record of the settings used.

Sheet materials for aligners include PET-G and various polyurethane and multilayer materials, in thicknesses that commonly range from about 0.5 to 1 mm. The choice depends on the stage of treatment, the movements planned and the dentist's preference. Retainers often use different materials than active aligners. Ask every supplier for the documentation that the material is intended for intraoral use.

Trimming and finishing

The trim line determines how the aligner holds and how comfortable it is. Cowley and colleagues showed that the height and shape of the edge change the retention of thermoformed aligners. At low volume, trimming by hand along a line marked on the model is enough. At higher volume, labs often move to a trimming machine that follows the digital trim line exported with the plan. After cutting, the edges are smoothed and polished, and each aligner is checked on its model.

The source of treatment plans

Planning is the step that most labs find hardest to start. A planner needs software, training in tooth movement and someone with orthodontic knowledge to review the plans. The alternative is an outside planning service that returns the models for each stage and the trim line, ready to print. A lab can also start with outsourced plans and move simple cases in-house later, when volume is steady.

Regulation

Aligners made by a lab on a dentist's written prescription for one specific patient are custom-made medical devices in the European Union. The Medical Device Regulation sets the rules for them in Article 52(8) and Annex XIII, including a statement for each device and documentation of how it was made. Serbia has its own medical device law, and other countries have their own regulators. Check the rules that apply in your country before you deliver the first aligners.

A start in eight steps

  1. Talk to the dentists you already work with and agree on how cases will be sent and approved.
  2. Decide where plans will come from, in-house or outsourced.
  3. Buy or check the printer, resin and post processing equipment.
  4. Choose a thermoformer and one or two sheet materials to start with.
  5. Write a short procedure for printing, forming, trimming, cleaning and packing.
  6. Make a few test series on models and check fit and edges.
  7. Prepare the regulatory documentation for custom-made devices.
  8. Start with simple cases and collect feedback from the dentist after every case.

Quality checks for every series

The first series show where the procedure needs work. Fit on the model, smooth edges and correct order of stages matter more at the start than speed.

Sources

  1. Ryu JH, Kwon JS, Jiang HB, Cha JY, Kim KM. Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic aligners. Korean J Orthod. 2018;48(5):316-325. https://doi.org/10.4041/kjod.2018.48.5.316
  2. Cowley DP, Mah J, O'Toole B. The effect of gingival-margin design on the retention of thermoformed aligners. J Clin Orthod. 2012;46(11):697-702.
  3. Regulation (EU) 2017/745 of the European Parliament and of the Council on medical devices, Article 52(8) and Annex XIII (custom-made devices). https://eur-lex.europa.eu/eli/reg/2017/745/oj

This article is general professional information for dental labs and dentists. It is not a diagnosis or a treatment plan for any patient. The treating dentist decides on every treatment.

Read next

Request early access

Published: . Updated: