How to prepare a scan for aligner planning
A scan is ready for aligner planning when both arches show every crown completely, including the distal surfaces of the last molars, with a few millimetres of gingiva, no holes or soft tissue artifacts, a correct bite registration, and files exported in millimetres as STL, PLY or OBJ. Most cases that come back from planning come back because one of these is missing.
What the planner needs from the scan
The planner separates every tooth from the gum, builds the parts of the crown the scanner cannot see, estimates the roots, and moves the teeth stage by stage. Every step depends on the surface of the scan. A missing contact point, a hole at the gum line or a bite that does not close changes the measurements and the final position. A plan built on a poor scan produces aligners that do not fit.
- Both arches, full, from the last erupted molar on one side to the last on the other.
- Complete crowns, including the interproximal areas as far as the scanner can reach.
- At least 3 to 5 mm of attached gingiva on the buccal and lingual sides, for the trim line.
- The palate is useful for the upper arch, as a stable reference.
- A bite scan or bite registration in maximum intercuspation.
- Files in millimetres, with upper and lower in the same coordinate system.
The errors that most often return a case
| Error | Why it is a problem | How to avoid it |
|---|---|---|
| Distal surface of the last molar missing | the aligner has no end stop, and the molar cannot be segmented | scan behind the last molar from occlusal, buccal and lingual angles |
| Holes at the gum line or between teeth | the tooth shape is guessed and the trim line has no surface | rescan the area, check the model before sending |
| Tongue, cheek or lip in the scan | soft tissue merges with teeth or gum | retract well, delete the artifact and rescan that area |
| Bite missing or open | the planner cannot check the occlusion | scan the bite on both sides in maximum intercuspation |
| Upper and lower not aligned | the arches cannot be put in occlusion | export both from the same scan session with the bite applied |
| Wrong units | teeth appear 25 times too small or too large | export in millimetres |
| Mesh reduced too much | fine detail and contacts are lost | export at full or high resolution |
| Old scan | teeth have moved since the scan | scan shortly before planning, and after any extraction or restoration |
| Brackets or old attachments on the teeth | the planner cannot see the real crown | remove them and polish before scanning, or tell the planner |
Accuracy of the scan itself
Intraoral scanners are accurate enough for aligners when used correctly. Mangano and colleagues reviewed 132 studies and concluded that intraoral scans are accurate enough for orthodontic appliances such as aligners, while noting a learning curve for the person scanning. Full arch scans are still the hardest case for a scanner. Ender and Mehl measured complete arch impressions in the laboratory and found the intraoral scanner they tested less accurate than conventional impressions, with deviations of tens of micrometres. Scanners have improved since then, but technique still matters most over the full arch, so follow the scanning strategy recommended by the scanner maker, keep the field dry, and check the result before the patient leaves.
STL, PLY or OBJ
All three formats describe the surface as triangles. STL carries only geometry. PLY and OBJ can also carry colour, which helps the planner see the gum line and restorations. Any of them works for planning. What matters more is that the export is in millimetres, not decimated too much, and that upper and lower are in the same position relative to each other.
Model scans
Labs that scan plaster models with a desktop scanner should check that the models are poured without bubbles on the teeth, that the bases do not hide the gum line, and that the bite is scanned with the models in occlusion. Impressions should be poured quickly according to the material's instructions, because distortion of the impression changes the model.
What to send with the scan
The scan alone does not describe the treatment. The planner also needs the dentist's instructions.
- What to correct and what the patient wants.
- Which teeth must not move, such as implants, ankylosed teeth or bridges.
- Whether interproximal reduction is allowed, and where not.
- Whether attachments are allowed.
- Planned extractions or restorations during treatment.
- Photos and a radiograph when the case needs them, for example to see root position.
Special situations
- Partly erupted teeth. Scan as much of the crown as is visible and mention the tooth in the instructions, because the planner has to leave room for eruption.
- Missing teeth and implants. Tell the planner which gaps should close, which should stay open for an implant, and which teeth are implants that must not move.
- Large restorations or crowns planned during treatment. Scan after the new restoration is done, or the aligners will not fit the new shape.
- Refinement scans. Scan with the attachments in place and the last aligner removed, so the planner sees the real position of the teeth.
A check before you press send
Open the exported files in a free viewer and look at them from all sides. Check the last molars, the gum line, the contacts and the bite. Make sure the files are named by arch, not by patient name. A two minute check saves a day of waiting for a rescan, and it saves the patient another appointment.
If a case does come back, ask the planner exactly which area was missing and keep a short list of the reasons. After a few cases, the list shows which step of the scanning routine needs attention, and the number of returned cases falls quickly.
Sources
- Ender A, Mehl A. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent. 2013;109(2):121-128. https://doi.org/10.1016/S0022-3913(13)60028-1
- Mangano F, Gandolfi A, Luongo G, Logozzo S. Intraoral scanners in dentistry: a review of the current literature. BMC Oral Health. 2017;17(1):149. https://doi.org/10.1186/s12903-017-0442-x
This article is general professional information for dental labs and dentists. It is not a diagnosis or a treatment plan for any patient. The treating dentist decides on every treatment.