Aligner sheet thickness and material: what changes the force on the teeth

The force a clear aligner applies depends on the sheet material, its thickness after thermoforming, how far the aligner is activated and how well it fits, so a lab should choose one validated material and thickness, keep the thermoforming process consistent, and let the plan control the size of each step. This article summarises what studies show and what it means for production.

What thermoforming does to a sheet

A thermoforming sheet starts with a nominal thickness, for example 0.75 mm. When it is heated and pulled over a model, it stretches and becomes thinner, more on tall and steep surfaces than on flat ones. Ryu and colleagues tested several aligner materials and found that thermoforming changed their thickness and their mechanical properties, so the aligner in the mouth is not the same as the sheet in the box.

A systematic review and meta analysis by Iliadi and colleagues looked at the forces and moments that aligner type appliances produce. Under the laboratory settings they analysed, sheet thickness did not appear to play a significant role in the forces and moments, and the authors noted that their findings apply mainly to laboratory conditions.

FactorEffect on forceWhat the lab controls
Sheet materialdifferent stiffness and how fast force decayschoose one validated material
Sheet thicknessthe effect on force is not clear in the evidenceuse one thickness per stage type
Thinning during thermoforminguneven thickness around the crownconsistent heating time and temperature
Activation per stagea bigger step gives higher initial forceset by the plan, not by the lab
Trim line and fitedge design changes force transmissionfollow the trim line from the plan

The trim line matters too

Elshazly and colleagues showed in an in vitro study that the trimming line design and how far the aligner edge extends affect force transmission. A higher, scalloped edge and a straight edge extended onto the gum behave differently. That is why the trim line belongs in the plan and should be followed in production, not cut by eye.

Consistency beats perfection

A lab cannot measure the force of every aligner, but it can keep the process the same: the same material, the same thickness, the same thermoforming settings, the same trimming. When results change, the cause can then be found. When everything changes from case to case, nobody knows why an aligner does not fit.

A production checklist

These checks take little time and catch most production problems before the aligners reach the dentist.

  1. Record the material, sheet thickness and batch for every case.
  2. Use the thermoforming settings recommended for that material and keep them fixed.
  3. Check the fit of the first aligner on the printed model before producing the rest.
  4. Follow the trim line from the plan and keep a photo of the trimmed edge.

Printed models and fit

The model under the sheet matters as much as the sheet. A printed model with visible layer lines, warping or poorly cured resin produces an aligner with the same defects. Small errors in the model become a tight or loose aligner, and the patient feels it immediately. Print settings, post curing and storage of models should be as consistent as the thermoforming.

Models should also include the attachments from the correct stage and should be printed hollow or solid according to what the thermoforming machine handles well. A model that deforms under heat and pressure gives an aligner that does not match the plan, even if the plan and the sheet are perfect.

Changing materials

Labs sometimes change materials because of price or availability. That is possible, but it should not happen in the middle of a case without a reason, because a different material can change how the aligners fit and feel. If a change is necessary, tell the dentist, and check the first aligners from the new material carefully on the model and in the mouth.

When introducing a new material for all cases, test it on a few simple cases first and compare the fit with the old material. Keep notes on thermoforming settings, trimming and patient comments. A small trial costs little compared with remaking aligners for many patients.

Suppliers usually publish recommended thermoforming settings for each sheet. Treat them as a starting point, check them on your own machine and then keep the values that work. Writing them down next to the machine is a simple way to make sure every technician uses the same settings.

Okluzo plans the stages and the trim line and does not sell sheets or machines. The lab chooses the material and keeps production under its own control.

Sources

  1. Ryu JH, Kwon JS, Jiang HB, Cha JY, Kim KM. Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic aligners. Korean J Orthod. 2018;48(5):316-325. https://doi.org/10.4041/kjod.2018.48.5.316
  2. Iliadi A, Koletsi D, Eliades T. Forces and moments generated by aligner-type appliances for orthodontic tooth movement: a systematic review and meta-analysis. Orthod Craniofac Res. 2019;22(4):248-258. https://doi.org/10.1111/ocr.12333
  3. Elshazly TM, Keilig L, Salvatori D, Chavanne P, Aldesoki M, Bourauel C. Effect of trimming line design and edge extension of orthodontic aligners on force transmission: an in vitro study. J Dent. 2022;125:104276. https://doi.org/10.1016/j.jdent.2022.104276

This article is general professional information for dental labs and dentists. It is not a diagnosis or a treatment plan for any patient. The treating dentist decides on every treatment.