STL, PLY or OBJ: which scan file to send for clear aligner planning
For clear aligner planning, any of the three common open formats works, STL, PLY or OBJ, as long as the export contains the full arch at full resolution; STL is the most widely supported, while PLY and OBJ can also carry colour, which helps the planner see the gum line. This article explains the differences and the export settings that matter.
What is inside a scan file
An intraoral scanner measures thousands of points on the teeth and gums and turns them into a surface made of small triangles, called a mesh. Each file format stores that mesh in a slightly different way. The geometry is the same; what differs is whether the file can also store colour, how big it is, and which software can open it.
Intraoral scanners have become accurate enough for full arch work in most clinical situations, according to reviews such as the one by Mangano and colleagues, and full arch accuracy has been measured in detail by Ender and Mehl. The file format does not change that accuracy, but a bad export can throw part of it away.
| Format | Colour | Typical use | Note |
|---|---|---|---|
| STL | no | the standard for dental CAD and 3D printing | opens everywhere, geometry only |
| PLY | yes, per point | scanner exports with colour | smaller than STL, keeps colour |
| OBJ | yes, with a texture file | scanner exports with colour | send the texture files together with the OBJ |
| Proprietary formats | yes | inside the scanner's own software | often encrypted, cannot be opened by others |
Why colour helps
The planner has to separate each tooth from the gum. On a colourless STL the border between enamel and gum is visible only from the shape of the surface, which is not always clear on lower incisors or around inflamed gums. With colour, the border is much easier to see. Colour is not required, but when your scanner can export PLY or OBJ with colour, send that.
- STL: send it when the scanner or the software offers nothing else.
- PLY: a good default when available, because colour is in the same file.
- OBJ: include the texture image and the material file, or the colour is lost.
- Do not send the scanner's proprietary format unless the planner has said they can open it.
Export settings that matter
Most problems come from the export, not from the format. The scanner software may reduce the mesh to make files smaller, cut the base, or export only one arch. Before sending a case, check the export once in a free viewer and compare it with what you saw on the scanner screen.
A quick export checklist
Use the same checklist on every case. It takes a minute and prevents most cases from coming back for a new scan.
- Both arches exported, each as a separate file, upper and lower clearly named.
- Full resolution, without decimation or smoothing in the export settings.
- A bite scan or the arches exported in occlusion, so the planner knows how they meet.
- No patient name in the file name. Use a case code instead.
What else the planner needs
The scan files are the core of a case, but they are not the whole case. The planner also needs to know what the dentist wants, and sometimes needs information that is not visible on the surface of the teeth. A complete case is the fastest case, because nothing has to be requested later.
Photos help when the scan does not show something clearly, for example the colour of a tooth that will be restored or the position of the lips. A panoramic X ray helps when roots, implants or impacted teeth matter for the movement. Not every case needs them, but when they are needed, sending them with the first upload saves a day.
- The dentist's instructions: goals, teeth that must not move, whether IPR is allowed.
- A bite registration or arches scanned in occlusion.
- Photos of the face and teeth when the dentist considers them useful.
- A panoramic X ray when roots, implants or missing teeth affect the plan.
- Information on existing restorations, crowns and bridges.
File size and upload
Full resolution scans are larger, often tens of megabytes per arch. That is normal and should not be a reason to reduce the mesh. A planning portal should handle files of that size without trouble. If an upload fails, the cause is more often the connection than the file, and uploading the arches one by one usually helps.
Compressing files into a ZIP archive is fine and can speed up the upload, but keep one case per archive and name the files clearly inside it. Do not mix files from different patients in one upload, even temporarily, because it is the easiest way to plan the wrong case.
Finally, keep a copy of what you sent. If the planner reports a problem with a file, you can check it immediately instead of exporting the case again from the scanner and wondering whether the new export is the same as the first.
The Okluzo portal, which is in preparation, will accept STL, PLY and OBJ, show the scan in 3D right after upload so you can check it, and keep the patient name out of all file names.
Sources
- Mangano F, Gandolfi A, Luongo G, Logozzo S. Intraoral scanners in dentistry: a review of the current literature. BMC Oral Health. 2017;17(1):149. https://doi.org/10.1186/s12903-017-0442-x
- Ender A, Mehl A. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent. 2013;109(2):121-128. https://doi.org/10.1016/S0022-3913(13)60028-1
This article is general professional information for dental labs and dentists. It is not a diagnosis or a treatment plan for any patient. The treating dentist decides on every treatment.